Product Name: Coupling Decoupling Network (CDN)
Compliant Test Standards: IEC / EN 61000-4-6
Application: 75 Ohm Coaxial Cables
Frequency Range: 150 kHz to 230 MHz
RF Input Voltage: 40 V (Max)
RF Input Connector: 50 Ω BNC (Female)
Voltage Rating: 310 V AC / 440 V DC (Line to Ground)
Current Rating: 1 Amp (Max)
AE and EUT Connections: 75 Ohm Female BNC
Common Mode Impedance:
150 kHz - 26 MHz: 150Ω ± 20Ω
26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω
80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
Voltage Division Factor: 9.5 dB +3 / -1
Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
Dimensions: 6 x 6 x 13 inches or 15.2 x 15.2 x 33 cm
Weight: 5 lbs. or 2.3 kg
Accessories Available from Com-Power for setting test levels and running the test:
ADA-C50/C75 shorting adapters
ADA-515-2 150 Ω to 50 Ω adapters
TEP-050 50 Ω Terminator
ATTN-6-100W Power Attenuator
DCU-300-100W Directional Coupler
ASC series Power Amplifiers