USD-15SX超聲波探傷儀
產(chǎn)品簡介:USD-15SX ultrasonic flaw detector
Product introduction:
The instrument is equipped with large electroluminescentdisplay (7.7 "x 3.8") (196 x 97mm), 3 independent controlgate and the 150 data storage unit, optional type PRF and has the highest 12KHz (pulse repetition frequency),40dB DAC/TCG, and the triangulation method of defect location, with letters and numbers named function dataand A scans and other. Radio frequency instrument is also provided with a radio frequency output and theoutput video display mode, including broadband, 8 optional frequency.
Characteristic.
· composite video output (50 Hz PAL);
· oscilloscope is compatible with RF output;
Connection, high speed data PC (computer interface card)
· detection range: 5.6-9906mm (P) in steel), 63.5-254mmcontinuously variable or pre grading;
· display: -25.4~5080mm (steel longitudinal wave);
· velocity: continuous adjustable 1.02-12.7mm/microsecond, two can be set to sound;
· probe delay: 0-999.99 microsecond;
· gain 0-110dB, 0.5dB step, can choose between 0.5/1.0/2.0/6.0, 0.5dB step from the 6.5dB default to 24dB;
· test mode: pulse echo method and the double probe method, pulses, the peak, the pulsar maximum 480V, rise time of <30 ns;
· charging the capacitor can be 220, 1000, and 2000pF by switching;
33, 50, 75, damping, and 500 ohm, can choose stepdamping;
· pulse repetition frequency: 1-1200 Hz (12KHz),automatic display and gate settings coupling or freely on the 50Hz step adjustment;
· amplifier bandwidth: narrowband filter 0.5, 1, 2, 2.5, 4, 5, 10, 15MHz, broadband 0.3-20MHz (-3dB);
· linear inhibition range 0-80% FSH; * vertical linear error+/-2%;
· triangulation location of defects;
RF display mode and the RF output, video output, can display the pulse of positive and negative half wave andfull wave;
· digital distance and amplitude measurement;
· analog output 0-5V (with optional DC compensation) and the amplitude ratio and distance (the gate optional);
· units inch and mm;
· optional pulsar power;
· the UD160 battery (not a nickel cadmium batterycharging) integral;
Automatic control operation;
· external clock;
· for all gates and time signal special 37 needle output connector and connect cable;
· distance amplitude correction (DAC) can record the 20 reference echo;
40dB dynamic range, the maximum slope 6dB/ microsecond;
· TCG, CGB (curve and gate A) display;
High brightness, high contrast electroluminescent screen 512x256pixels (195x97mm);
· thickness resolution to read 0.025mm (precision up to 0.0127mm);
· 3 independent monitoring gate (a can be used as interface wave gate) in the display range is adjustable,the gate can be display sound path, the projection distance, depth, to screen high percentage or and gatethreshold or stored reference wave dB differential displaysignal amplitude;
A scanning function: display options are available including a signal peak preservation, freezing, and display the average correction mode finally 2-16 frame;
· data storage of up to 100 A scan data as well as all of the instrument sets, including the DAC;
Dialogue language can choose: English, German, Italian,Portuguese, and Spanish;
· print test reports including the parameters of the apparatus, A scan and DAC curve;
· interface and output: RS 232C connection communication, can be connected to the printer / computer, speed up to 19200 Potter, 37 pin interface for each gate in the pulse repetition frequency synchronization, synchronization output, alarm reset, the experimental data is released under the real-time alarm output and analog output (range time or amplitude);
· AC operation: direct input 90V-264V 50/60Hz AC power supply, automatic identification and selection; battery:battery charging operation inside and outside, you can use the 12V alkaline batteries or nickel cadmium type "D"external rechargeable battery, charging time 5 hours, can make the external charging;
Working temperature: -18~54 ℃; storage temperature:-29~66 ℃;
· size: 7.56 "x 14.41" x 13.5";
· weight without battery: 19 pounds, 22 pounds withbattery