TP101A精密型差壓儀TP-101A差壓計
TP101A精密型差壓儀在采暖、通風、空氣調節、環境監測、節能監測、氣象、農業、冷藏、制藥、凈化室測試及標定壓力等方面均有廣泛的用途。
技術指標
主要功能
*手動差壓調零校準功能
* 顯示測量值定格功能
* 顯示屏背光開關功能
* 可設置環境補償參數功能
* 大屏幕點陣式LCD顯示
技術說明
* 測量范圍: 差壓0~±1000Pa,風速1~40m/s
*測量精度: 差壓: ±1%FS。風速(搭配皮托管):±5%FS。
*最小分辨率:差壓:1Pa;風速: 0.1 m/s
*工作溫度:0~50℃,相對濕度:≤85%RH。
電源:1 節9V堿性電池。連續工作時間不小于10小時。
使用注意事項
* 在風速測量中,必須使皮托管上的全壓口對準來風方向。
* 盡量使用較短的引壓管,長度不宜超過3米。
* 差壓最好不要超過±1000 Pa,否則,因壓力過大造成的傳感器損壞不在保修范圍之內。
* 儀表自出廠之日起,一年內如因制造不良而工作不正常,廠負責免費更換或修理其損壞的零部件。
* 為保證儀表測量的準確性,用戶應每年在計量部門認可的專用設備上進行校準。如當地不具備條件可由本廠代為校準。
* 本廠在生產和銷售的過程中,如遇型式、包裝、規格等方面的改變,恕不另行通知。
儀表的保管與運輸
* 儀表應放在通風、干燥、沒有腐蝕性氣體及強烈的機械振動和強磁場影響的室內。
* 長期不用的儀表,應將電池取出,以免損壞儀表。
* 儀表在運輸過程中,應注意防震、防潮、防雨、防曬。
隨貨提供
* TP101A主機……………………………………1臺
* 1米硅軟管Φ4×6mm…………………………2根
* 產品使用說明書………………………………1份
* 產品合格證……………………………………1份
* 9V堿性電池……………………………………1節
* 便攜箱 …………………………………………1個
選配件
* 皮托管
TP101A precision pressure meter TP-101A meter
TP101A precision differential pressure instrument in theheating, ventilation, air conditioning, environmental monitoring, energy monitoring, meteorological,agricultural, cold storage, pharmaceutical, clean roomtesting and calibration of pressure and has wide application.
Technical indicators
Main function
* manual pressure zero calibration function
* display measured values freeze function
* display backlight switch function
* can set the environment compensation function
* large screen dot matrix LCD display
Technical note
* measurement range: differential pressure 0 ~ + 1000Pa,the wind speed of 1 ~ 40m/s
* the measurement accuracy: differential pressure: ± 1%FS. The wind speed (with a pitot tube): + 5%FS.
* minimum resolution: differential pressure: 1Pa; wind speed: 0.1 m/s
* operating temperature: 0 ~ 50 ℃, relative humidity: ≤ 85%RH.
Power: 1 9V alkaline batteries. Continuous working timeis not less than 10 hours.
Use the matters needing attention
* in measuring wind speed, must make full pressure port at wind direction pitot tube.
* use a pressure guiding pipe is short as far as possible,is more than 3 metres in length.
* pressure should not exceed ± 1000 Pa, otherwise,sensor damage due to excessive pressure causes is notwithin the scope of the warranty.
* the instrument from the factory the day, within a year as a result of the ill manufacturing is not working properly,plant is responsible for replacement or repair thedamaged parts free of charge.
* in order to ensure the measuring accuracy, the usershould be calibrated at least annually in specialequipment measuring departments approved. If the localdoes not have the conditions by the factory forcalibration.
* the factory in the process of production and sales, such as the case of type, packaging, specifications and otheraspects of change, without notice.
Storage and transport instrument
* the instrument should be no effect of corrosive gas andstrong mechanical vibration and strong magnetic field in the ventilation, drying, indoor.
* without long-term instruments, should remove the battery, so as not to damage the instrument.
* instrument in the transportation process, should pay attention to moistureproof, waterproof, shockproof,sunscreen.
With the cargo to provide
* TP101A host.......................................... 1
* 1 m Φ 4 × 6mm silicon hose.............................. 2 root
* the product manual.................................... 1
* product certificate.......................................... 1
* 9V alkaline batteries.......................................... The 1 Section
* portable box................................................ 1
Optional accessories
* the pitot tube