EXTECH7440安規測試儀
東莞市新創通用儀器有限公司
二手測試儀器測量儀表;銷售;回收;維修;租憑;等相關業務主營
歐陽浩;13712204729、騰訊QQ;1908563118
電話;0769-81001545
高價上門回收二手儀器儀表;價格公道,童叟無欺,歐陽經理
華儀7440安規綜合分析儀特點
交/直流耐壓、絕緣阻抗、接地阻抗測試
20 × 2 點矩陣OLED 顯示器
可選配內建4組或8組高壓矩陣式掃描信道(7420, 7430 & 7440)
內建50組程序記憶、每一組8個測試步驟可進行程序記憶步驟的連結測試
測試線路阻抗自我歸零校整功能,確保測試結果的準確性
前面板軟件輸入校正
內建PLC Remote遙控界面
鍵盤鎖定功能
可外接標準GPIB、USB & RS232、Printer Card 作控制
全范圍電壓輸出的穩壓率在1%以內
EXTECH 7440安規綜合測試儀規格
MODEL |
7410 |
7420 |
7430 |
7440 |
AC WITHSTAND VOLTAGE |
||||
Output Rating |
5KVAC / 30mA |
5KVAC / 30mA |
5KVAC / 40mA |
5KVAC / 40mA |
|
Range |
Resolution |
Accuracy |
|
Output Voltage,ACV |
0 - 5000 |
1 |
±(2% of setting + 5V) |
|
Output Frequency |
50Hz / 60Hz ± 0.1%, User Selectable |
|||
Output Waveform |
Sine Wave ,THD. < 2% (Resistive Load), Crest Factor = 1.3 - 1.5 |
|||
Output Regulation |
± (1% of output + 5V), From no load to full load |
|||
SETTINGS |
||||
Hi-Limit AC Current, mA |
0 - 30.00 |
0 - 30.00 |
0 - 40.00 |
0 - 40.00 |
Resolution : 0.01, Accuracy : ±(2% of setting + 3counts) |
||||
Lo-Limit AC Current, mA |
Range : 0 - 9.999 |
|||
Resolution : 0.001, Accuracy : ±(2% of setting + 3counts) |
||||
Ramp Time, second |
0.1 - 999.9 |
0.1 |
±(0.1% + 0.05sec) |
|
Dwell Time, second |
0, 0.3 - 999.9 |
0.1 |
||
Arc Detection |
The range is from 1 - 9 (9 is the most sensitive) |
|||
AC Current Offset, mA |
0 - 2.000 or Auto Set |
|||
DC WITHSTAND VOLTAGE |
||||
Output Rating |
6KVDC/9999μA |
|||
Output Voltage, DCV |
0 - 6000 |
1 |
±(2% of setting + 5V) |
|
Output Ripple |
< 5% (6KV / 9999 μA at Resistive Load) |
|||
SETTINGS |
||||
Hi-Limit DC Current, μA |
0 - 9999 |
1 |
±(2% of setting + 3counts) |
|
Lo-Limit DC Current, μA |
0 - 999.9 |
0.1 |
±(2% of setting + 3counts) |
|
Ramp Time, second |
0.1 - 999.9 |
0.1 |
± (0.1% of setting + 0.05s) |
|
Dwell Time, second |
0, 0.4 - 999.9 |
0.1 |
||
Arc Detection |
The range is from 1 - 9 (9 is the most sensitive) |
|||
DC Current Offset, ?A |
0 - 200.0 or Auto Set |
|||
Ramp High Current |
ON/OFF, User Selectable |
|||
Charge - Low Current, μA |
0 - 350.0 or Auto Set |
|||
Discharge Time |
≦ 200 msec |
|||
INSULATION RESISTANCE |
||||
Output Rating |
1KVDC / 9999MΩ |
|||
Output Voltage, DCV |
100 - 1000 |
1 |
± (2% of setting + 3V) |
|
Hi-Limit Resistance, MΩ |
0, 1 - 9999 (0=OFF) |
1 |
100 - 499V |
|
Lo-Limit Resistance, MΩ |
1 - 9999 |
1 |
||
Delay Time, second |
0, 0.5 - 999.9 |
0.1 |
±(0.1% + 0.05sec) |
|
Charge - Low Current, μA |
0 - 3.500 or Auto Set |
|||
GROUND BOND (7440 ONLY) |
||||
Output Rating |
30A / 600mΩ, 8V |
|||
Output AC Current, A |
3.00 - 30.00 |
0.01 |
± (2% of setting +3 counts) |
|
Output AC Voltage, V |
3.00 - 8.00 |
0.01 |
± (2% of setting +3 counts) at Open circuit |
|
Output Frequency |
50Hz/60Hz ±100ppm, User Selectable |
|||
SETTINGS |
||||
Hi-Limit Resistance, mΩ |
0 - 150 (3 - 30A) |
1 |
± (2% of setting +2 counts) |
|
Lo-Limit Resistance, mΩ |
0 - 600 (3 - 10A) |
|||
Lead Resistance Offset, mΩ |
0 -200 |
1 |
± (2% of setting +2 counts) |
|
Dwell Time, second |
0, 0.5 - 999.9 sec (0=continuous) |
0.1 |
± (0.1% of setting + 0.05s) |
|
MEASUREMENT |
||||
AC/DC Voltage, KV |
0 - 6.00 |
0.01 |
±(1.5% of reading ) > 500V |
|
DC Voltage, V (IR) |
100 - 1000 |
1 |
±(1.5% of reading + 3V) |
|
AC Current Range, mA |
0 - 3.500 |
0 - 3.500 |
0 - 3.500 |
0 - 3.500 |
3.00 - 30.00 |
3.00 - 30.00 |
3.00 - 40.00 |
3.00 - 40.00 |