CPU 416-3PN
6ES7416-3ES07-0AB0
SIMATIC S7-400, CPU 416-3 PN/DP CENTRAL PROCESSING UNIT WITH: 16 MB WORKING MEMORY, (8 MB KB CODE, 8 MB DATA), INTERFACES: 1. IF MPI/DP 12 MBIT/S (X1), 2. IF ETHERNET/PROFINET (X5), 3. IF IF964-DP PLUGABLE (IF1)
SIPLUS S7-400 CPU 416-3 PN/DP -25 ... +70 攝氏度 帶防腐蝕涂層 基于 6ES7416-3ES07-0AB0 。 中央處理器,帶: 工作存儲器 16 MB, (8 MB 代碼,8 MB 數據), 接口 第 1 個 MPI/DP 接口 12 MBIT/S(X1), 第 2 個以太網/PROFINET 接口(X5) 第 3 個 IF 964-DP 接口可插拔(IF1)
上海勵輝自動化科技有限公司愿為您解答任何有關 SIEMENS 可編程控制器及變頻器的技術問題,并提供詳細的技術資料。公司還在某大型研究所內設有設施一流的培訓中心,定期舉辦 S7 - 200/300 及變頻器、全數字直流調速裝置的技術培訓班,為您盡快掌握 SIEMENS 自動化產品的使用提供便利。西門子PLC模塊,西門子變頻器,西門子觸摸屏,西門子通訊電纜,西門子伺服驅動,西門子軟啟動器,西門子工控機,西門子交換機,自動化科技專業領域內的技術研發、技術服務,銷售自動化控制設備、電氣設備、五金交電、電子元器件、電子設備、儀器儀表、電線電纜、機電設備。
本公司主要是通過電子商務經營大眾消費品,消費品行業所有知名品牌產品等。本公司秉承“顧客至上,銳意進取”的經營理念,堅持“客戶第一”的原則為廣大客戶提供優質的服務。歡迎廣大客戶惠顧!
聯系人:郭金秀
24小時銷售及維修熱線:15216632215
手 機:15216632215 Q Q : 498588739
郵箱:498588739@qq.com
地址:上海市松江區廣福林路4855弄19號4樓
概述
-
高端性能范圍內的高性能 CPU
-
適用于對性能要求很高的工廠
-
CPU 416-3 PN/DP 中集成了 PROFINET 功能
應用
CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.
The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.
An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.
The integrated PROFINET interface of the CPU 416-3 PN/DP includes switch functionality when the ERTEC 400-ASIC is used. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.
Note:
Only the 6ES7 964-2AA04-0AB0 interface submodule may be used.
設計
Both CPUs are equipped with the following:
-
Powerful processor:
The CPUs achieve instruction execution times as low as 0.03 μs per binary instruction.
-
CPU 416-2: 5.6 MB RAM (of which 2.8 MB each for program and data);
CPU 416-3: 11.2 MB RAM (of which 5.6 MB each for program and data);
CPU 416-3 PN/DP: 11.2 MB RAM (of which 5.6 MB each for program and data);
fast RAM for parts of the user program relevant to execution.
-
Flexible expansion:
Up to 262144 digital and 16384 analog inputs/outputs.
-
Multi-point interface MPI:
With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
-
Mode selector switch:
Designed as toggle switch.
-
Diagnostics buffer:
The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
-
Real-time clock:
The date and time are appended to diagnostic messages of the CPU.
-
Memory card:
For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available
-
Combined MPI/DP interface and integrated PROFIBUS DP interface (CPU 416-2 and CPU 416-3):
The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming).
Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.
CPU 416-3 and CPU 416-3 PN/DP also include:
-
A module slot:
An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module.
CPU 416-3 PN/DP additionally includes:
-
PROFINET interface with 2 ports (switch):
-
PROFINET I/O, 256 IO devices connectable
-
PROFINET CBA
功能
-
Block protection:
A password concept protects the user program from unauthorized access.
-
Integral HMI services:
The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
-
Integrated communications functions:
-
PG/OP communication
-
Shared data communication
-
S7 standard communication
-
S7 communication
-
Firmware update using network
CPU 416-3 PN/DP additional:
-
Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
-
Distributed intelligence in Component Based Automation (CBA) on PROFINET
-
Additional diagnostic options with integrated web server
Parameterizable attributes
The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.
-
Multi-point interface MPI:
-
Definition of station addresses.
-
Startup/cycle behavior
-
Stipulation of the maximum cycle time and communications load
-
Address assignment:
Addressing of I/O modules.
-
Retentive ranges:
Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.
-
Size of the process image, local data.
-
Length of the diagnostics buffer
-
Protection level:
Definition of access authorization for program and data
-
System diagnostics:
Definition of the handling and scope of diagnostic messages
-
Timed interrupts:
Setting of periodicity
CPU 416-3 PN/DP additional:
-
PROFINET interface
-
Parameterization of time synchronization using NTP procedure
Indication and information functions
-
Status and error indicators:
LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example
-
Test functions:
The programming device can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components
-
Information functions:
The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories