A. load capacity indicator:
The 5 indicators show the load capacity. From bottom to top is 17%, 34%, 51%, 68%, 85%. For example, if three lights lit, said at the UPS connection for the load capacity of 51% to 68%. To thoroughly test the entire system, to ensure that the UPS will not overload.
B.0nline status indicator:
UPS commercial power, to provide power for the connected device.
C. battery power indicator:
When the electricity fails, UPS can be a period of time with its internal battery powered equipment connected to. Powered by batteries, UPS issued a warning every 30 seconds (4 'beep' sound). When UPS returns0nline operation, the alarm stopped.
D. bypass indicator:
The indicator light, said UPS is in a 'bypass' mode. In this mode, the use of battery powered spare not, electricity is directly delivered to the connected load.
E: overload indicator:
When overload occurs (., the connected equipment exceeds the maximum load defined by UPS), the UPS will emit a continuous warning sound, which is bright.
F: fault indicating lamp:
When the lamp is bright, said UPS detected an internal fault.
G: replace battery indicator:
If the battery fails to pass the self-test, UPS will send a short 'beep' sound for 1 minutes, and replace the battery indicator light at the same time. If you replace the battery lights, said battery disconnected. UPS repeats alarms every 5 hours. You should check whether the battery pack is connected properly. If it is properly connected, the battery is checked 24 hours after the battery is checked to determine whether the battery needs to be replaced. If the battery through the self-test, the alarm will stop.
H: battery charging indicator / city voltage:
The 5 indicator shows the percentage of current storage capacity UPS battery battery capacity. From bottom to top are 0%, 24%, 48%, 72%, 96%. When the 5 all the bright lights when the battery is fully charged, said. When the battery capacity is reduced when the lights go out0ne by0ne from top to bottom. When the battery capacity is too low, all the bright lights (corresponding to a given capacity) will flicker, and UPS will stop humming to warn. Low battery alarm time, can use the terminal mode or through PowerChute software to change.
Press and hold the power button, the 5 indicator displays the voltage. From bottom to top is 192V, 210V, 229V, 248V, 266V.