Sensing Mode (General)Proximity
Sensing Mode (Detailed)Time of Flight
Housing StyleBarrel
Primary Housing MaterialPBT
Input/OutputDiscrete
IndicatorLED(s)
Analog Resolution/Discrete Repeatability /- 0.25 of measured distance (0.5 min)
Max Sensing Distance (mm)1000
Minimum Sensing Distance (mm)150
Sensing BeamUltrasonic
Power Supply12-24 V dc
AdjustmentsTeach Button
Temperature Effect (mm/°C)0.2 of sensing distance/°C
ConnectionIntegral QD
QD Type/Cable LengthM12 (Euro) requires mating cordset
Number of Pins5
VibrationMIL-STD-202F req. Method 201A (vibration:10 to 60Hz max double amplitude 0.06", max acc. 10G).
Mechanical ShockIEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage PNP Outputs< 1.0 V at 10 mA ; < 1.5 V at 100 mA
Max Discrete (Switched) Output (mA)100
Discrete (Switched) Outputs2 PNP
Output ProtectionProtected against false pulse on power-up and continuous overload or short-circuit of outputs
IP RatingIP67
NEMA RatingNEMA 6
Max Operating Temperature (°C)70
Min Operating Temperature (°C)-20
Max Op. Relative Humidity Non-Condensing ()100
Warm-up Time (minutes)15
Minimum Response Time (ms)48
Barrel Diameter (mm)30
Minimum Window Size (mm)10
Remote Teach and Laser Control Input Impedence55 k?
Discrete Output Hysteresis (mm)2.5
Ultrasonic Frequency (kHz)228
Max Off-state Leakage Current (μA)10
Power/Current Consumption (exclusive of load)90 mA
Supply Protection CircuitryProtected against reverse polarity and transient overvoltages
Feature: Remote TeachYes
Feature: Clear Object DetectionYes
Feature: Timing (Hold/Delay)No
Feature: Chemical ResistantNo
Application: UltrasonicYes
IO LinkNo
RS-232No
RS-422No
RS-485No
SSINo
WirelessNo
1-wire Serial InterfaceNo
ProfibusNo